16
0 10 20 30 40 50 60 70
20
40
60
80
100
21VDC 23VDC 30VDC (HORIZONTAL)
20
40
60
80
100
(E)Derating
Battery Input Voltage (V) - 24V Model
Ambient Temperature ( )℃
Figure 7.2: Output Derating Curve Figure 7.3: Input Derating Curve
(F) Notes on Output Loads:
TN/TS-15 0 0 Ser ies can power most of equipme nts t hat need an AC
source of 1500W. But for certain specific typ e of load, th e unit may n ot
work properly.
(1)Since inductive loads or motor based equipments need a large start up
(2)When the output are capacitive or rectified equipments (such as switching
current (6~10 times of its rated current), please make sure this start up
power supply), we suggest operating these equipment at no load or light
load condition. Increase the loads slightly only after the TN/TS-1500 has
started up to ensure proper operation.
current is less than the maximum current capability of the inverter.
Chassis
Cat.No.(1GG1HS-212)
Suitable wires (10-4 AWG
tinned copper wires)
Torque (17.7-26.5 in-lbs)
Comentários a estes Manuais